RPA-V1 Rubber Process Analyzer Specification

  • Measuring Range
  • ML 1+4 (100C) ~ ML 1+4 (200C)
  • Automation Grade
  • Automatic
  • Number of Specimens
  • 1
  • Accuracy
  • 0.5% F.S
  • Port Size
  • 8mm (Air inlet)
  • Product Type
  • Rubber Process Analyzer
  • Features
  • Programmable, Data Storage, Automatic Calculation
  • Application
  • Industrial
  • Response Time
  • Instantaneous (High-Speed Processor)
  • Gas Pressure
  • 0.5-0.7 MPa
  • Max Height
  • 550 mm
  • Frequency
  • 50Hz
  • Power Supply
  • Electric
  • Mounting Type
  • Tabletop
  • Humidity
  • 80% RH
  • Hardness
  • Compatible up to 85 Shore A
  • Specimen Size
  • 0.1mm Precision Slot
  • Interface Type
  • USB, RS232
  • Resolution
  • 0.001 Nm (Torque)
  • Display Type
  • Digital LCD with Graphical Output
  • Temperature
  • Room Temp 200C
  • Operating Voltage
  • 220V
  • Capacity
  • 1 Specimen at a time
  • Machine Weight
  • 180kg
  • Test Speed
  • 0.01-5 Hz
  • Test Width
  • 62 mm
  • Test Stroke
  • 0.5 (Oscillation)
  • Control Mode
  • Microcomputer Control
  • Repeatability
  • ±0.01 Nm
  • Maintenance
  • Low, Tool-Free Access
  • Sample Loading
  • Manual
  • Software
  • Proprietary RPA Data Evaluation Software
  • Sensor Type
  • High Precision Torque Sensor
  • Cooling Method
  • Forced Air Cooling
  • Heating Method
  • Electric Heating Plate
  • Color
  • White and Blue
  • Safety Features
  • Over-Temperature Protection, Emergency Stop
  • Calibration
  • Included, In-built Auto-calibration
  • Power Consumption
  • <500W
  • Additional Product Specifications
  • Ambient Temperature Range
  • 15°C-35°C
  • Data Output
  • Graph/Report Export (CSV, EXCEL)
 

RPA-V1 Rubber Process Analyzer Trade Information

  • Minimum Order Quantity
  • 1 Set
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 30 Sets, , Per Month
  • Delivery Time
  • 45-90 Days
  • Main Domestic Market
  • All India
 

About RPA-V1 Rubber Process Analyzer

Functions
  • Analyzes the characteristics of rubber samples before, during and after curing.
  • Provides frequency scanning, strain scanning, temperature scanning, and time scanning.
  • 3. Conducts testing in compliance with ASTM D6204.


Advanced Measurement Technology

The RPA-V1 utilizes a high-precision torque sensor and microcomputer control to deliver accurate rubber property analyses. Its instantaneous high-speed processor ensures responsive measurement while its digital LCD displays easy-to-read graphical outputs for effective monitoring.


Reliable Safety & Ease of Maintenance

Over-temperature protection and emergency stop mechanisms offer assured operational safety, while tool-free access simplifies routine maintenance. Auto-calibration is built in, ensuring consistent accuracy without manual intervention, saving both time and effort.


Comprehensive Data Analysis & Export

With proprietary RPA data evaluation software, users can capture detailed measurements and export reports in CSV or Excel formats. Programmable features include automatic calculation for streamlined data storage and analysis, making output accessible and actionable.

FAQs of RPA-V1 Rubber Process Analyzer:


Q: How do I use the RPA-V1 Rubber Process Analyzer for rubber testing?

A: To use the RPA-V1, manually load one specimen into the precision slot. Set your test parameters using the microcomputer control, then start the analysis. Results are displayed on the digital LCD and data can be exported in CSV or Excel formats for further evaluation.

Q: What safety features are integrated into the RPA-V1?

A: The analyzer includes over-temperature protection to prevent overheating and an emergency stop button for immediate shutdown in case of emergencies, ensuring a safe operating environment throughout the testing process.

Q: When should I perform calibration on the RPA-V1 device?

A: Calibration is performed automatically thanks to the built-in auto-calibration feature. No manual calibration is needed, ensuring accurate and consistent results before every test cycle.

Q: Where is the RPA-V1 suitable for installation?

A: The RPA-V1 is designed for tabletop use in industrial settings, such as manufacturing facilities, laboratories, or quality control environments, with a recommended ambient temperature of 15C to 35C and humidity up to 80%% RH.

Q: What are the benefits of using the RPA-V1 Rubber Process Analyzer?

A: The RPA-V1 offers precise, repeatable testing with high accuracy, immediate data processing, robust safety features, and easy maintenance. Its programmable software, direct data export, and rapid response time make it ideal for optimizing rubber product quality and research.

Q: How is specimen loading and measurement conducted in the analyzer?

A: Specimen loading is manual, allowing for careful placement in the analysis chamber. Measurements are conducted automatically according to the set parameters, with one specimen analyzed at a time for enhanced precision.

Q: What applications are suitable for the RPA-V1 Rubber Process Analyzer?

A: The RPA-V1 is tailored for industrial applications, especially for manufacturers and suppliers in the rubber industry, and delivers reliable property analysis for research, development, and quality assurance purposes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email